D.T.S. JACK Manuel d'utilisateur Page 11

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 10
11
8- VOLTAGE AND FREQUENCY
The JACK with electronic ballast can operate at 90-260 VOLT 50 or 60 Hz.
9- INSTALLATION
JACK may be either floor or ceiling mounted.
For floor mounting installations, the JACK is supplied with four rubber mounting feet
on the base.
For ceiling mounted installations, we reccomend the use of appropriate clamps to fix
the unit to the mounting surface.
The supporting structure from which the unit is hung should be capable of bearing the
weight of the unit, as should any clamps used to hang it.
The structure should also be sufficiently rigid so as not to move or shake whilst the
JACK is moving.
Four 1/4 turn Fast Locks connections placed in the base of the unit allow to hang the
JACK by using the Fast Lock “C” clamps provided in the box.
9.1- Safety cable
We recommend the use of a safety cable or chain connected to the JACK and to the
suspension truss in order to avoid the fixture accidentally falling should the main fixing
point fail.
Make sure that the iron cable or chain can bear the weight of the entire unit.
You may attach the safety chain/cord to the attachment point (A) located on the base
of the fixture, as shown in the picture below.
!
SAFETY CHAIN/CORD
ATTACHMENT POINT